hello@brookvent.co.uk+44 (0)28 9061 6505
  • GB
    • Rep. of Ireland
    • Poland
    • Lithuania
    • Estonia
    • Latvia
    • Hungary
    • Bulgaria
    • Germany
    • Spain
  • Services/Info
    • CAD System Design
    • Register Warranty
    • Building Regulations UK, Ireland, Northern Ireland
    • Energy Savings Trust
    • SAP Appendix Q
  • About
    • Who we are
    • Why Choose Brookvent
    • Industry Sectors
    • Accreditations
    • Awards
    • Careers
    • Corporate Social Responsibility
  • Contact
    • Contact Us
    • Office Locations
    • Terms & Conditions
    • Delivery & Returns
    • Faulty Product
    • Privacy Policy – Brookvent
    • Sitemap
Top Bar
Quick Search
£0.00
Brookvent UK and IrelandBrookvent UK and Ireland
Brookvent UK and Ireland
Mechanical ventilation, Heat Recovery Ventilation and Window Ventilation, Northern Ireland, UK Mainland
  • Heat Recovery
    Ventilation
    • Heat Recovery Ventilation Introduction
    • aircycle Status Indicator
    • aircycle 1.2 Heat Recovery Ventilation System
    • Aircycle 1.3 Heat Recovery Ventilation System
    • Aircycle 1.3 Digital Range Heat Recovery Ventilation
    • Aircycle 3.1 Heat Recovery Ventilation
    • Aircycle 3.1 Digital Range Heat Recovery Ventilation
    • Aircycle 4.1 Heat Recovery Ventilation
    • Aircycle 4.1 Digital Range Heat Recovery Ventilation
    • Aircycle ONE PRO Single Room Heat Recovery
    • Aircycle ONE Single Room Heat Recovery Ventilation
    • Aircycle ONE+ Single Room with Controller Heat Recovery Ventilation
    • Refurbished Aircycle Heat Recovery Ventilation System
    • Heat Recovery FAQ’s/ Information
    • NOX 50
    • NOX 100
  • Mechanical
    Ventilation
    • Mechanical Ventilation Introduction
    • Airstream ACE Mechanical Extract Ventilation (MEV)
    • Airplus Positive Input Ventilation (PIV)
    • Airstream Decentralised Mechanical Extract Ventilation (DMEV)
    • Airstream 1.1 E (MEV)
    • Airstream 1.1 EH (MEV)
    • Airstream Xe Intermittent Extract Fan
    • Airstream Xe+ Intermittent Extract Fan
    • AP Evo Air Purifier
    • Mechanical Ventilation FAQ’s/ Information
  • Commercial
    Ventilation
    • Roof fans
      • BMV PRO EC
      • BMV PRO EC Vertical
      • BVK PRO
    • Inline fans
      • BTP EC Duct Fan
      • BSB PRO EC
    • Axial fans
      • BKO
    • Jet fans
      • BSO PRO
      • BSP PRO
      • BOG
  • Ducting,
    Accessories
    & Filters
    • Introduction
    • airduct FIREBRICK
    • Rigid PVC Ducting
    • Semi Rigid Ducting
    • Attenuation
    • Fire Sleeve
    • Replacement Parts
    • Valves and Grilles
    • Accessories
    • Filters
  • Vents
    • Introduction
    • Surface Mounted / Throught The Frame Vents
      • SM 1000
      • SM 1000+
      • SM 1200
      • SM 1200+
      • SM 1400
      • Tipvent EVOLUTION
      • Tipvent
      • Acoustic Vents
    • Glazed In Vents
      • DG 1500
      • DG Standard
      • Thermal Break
      • DG 75
      • DG 80
      • DGL 80
      • DGL SUPER
    • Over Frame Vents
      • OF STANDARD
      • OF ACO
      • OF ACO+
      • OF SUPER
    • Acoustic Vents
      • PRESTIGE ACOUSTIC
      • SM Acoustic
      • SM Ultima
      • OF ACO
      • OF ACO+
      • OF Super
      • DGL Super
      • SM HY
    • Specialist Vents
      • Gas Vent (Always open)
      • Humidity control
      • Ultra high weather
    • Wall Vents
      • Introduction
      • Aquwall HY+/ Aquwall SI HY+
      • Aquwall Press
  • Heat Pump
    • Airtherm Aqua 1.1
    • Airtherm Aqua 1.2
    • Airtherm SPLIT Heat Pump
    • Airtherm MONO Heat Pump
  • News
    • News
    • Blogs
    • Projects
  • Louvres
    • Standard ventilation louvres
      • Flanged Wall Louvres
        • BRL20V-FL
        • BRL34V-FL
        • BRL34Z-FL
        • BRL50Z-FL
        • BRL60Z-FL
        • BRL65Z-FL
        • BRL75Z-FL
      • Glazed-in Louvres
        • BRL20V-GL
        • BRL34V-GL
        • BRL34Z-GL
        • BRL50Z-GL
        • BRL60Z-GL
      • Surface Mounted Louvres
        • BRL20V-SM
        • BRL34Z-SM
      • Screening Louvres
        • BRL20V-FL
        • BRL20V-GL
        • BRL20V-SM
    • Ventilation Louvres with increased flow area (HF)
      • Flanged Wall Louvres
        • BRL34Z-FL HF
      • Glazed-in Louvres
        • BRL34Z-GL HF
      • Surface Mounted Louvres
        • BRL34Z-SM HF
    • Ventilation Louvres with increased water resistance (EWR)
      • Flanged Wall Louvres
        • BRL34Z-FL EWR
        • BRL50Z-FL EWR
        • BRL60Z-FL EWR
        • BRL65Z-FL EWR
        • BRL75Z-FL EWR
      • Glazed-in Louvres
        • BRL34Z-GL EWR
        • BRL50Z-GL EWR
        • BRL60Z-GL EWR
      • Surface Mounted Louvres
        • BRL34Z-SM EWR
    • Door Louvre
      • BRL-DR
  • Thermoscreens
    • Air Curtain Products
    • Surface Mounted Air Curtains
      • C Series
      • C Series Designer
      • Compact 2
      • HP Series
      • HX Series
      • HX CS Cold Store
      • IP Series
      • Jet3 overdoor heater
      • PHV
      • PHV Designer
      • PHV Vertical
      • T Series
      • EcoPower Remote Control
    • Recessed
      • C Series
      • Compact 2
      • HX Series
      • PHV
      • T Series
      • T600 and T800 Thermal Air Heaters
      • EcoPower Remote Control and Monitoring
  • Biddle
    • Climate Control Solutions
    • Comfort Air Curtains
      • SR Air Curtain
      • Invisidor City Comfort Air Curtain
      • Invisidor Style Designer Air Curtain
      • Invisidor Doorflow Comfort Air Curtain
    • Industrial Air Curtains
      • Indac2 Air Curtain
      • IsolAir2 Chilled Room Air Curtain
      • MAT Cold Store Air Curtain
    • Industrial Heaters
      • Noz2 Ceiling Mounted Industrial Cooling
      • Noz2 Ceiling Mounted Industrial Heater
      • Uniflow Air Heater
    • Heating & Ventilation
      • Innovair Fresh Air Fan Convector
      • Comfort Circle
      • Forceflow H2
      • Forceflow LST Fan Convector
      • Forceflow CB Fan Convector
      • DECOQT Fan Coils
    • Heat Recovery
      • Air2Air Heat Recovery Solutions
    • Fan Coils
      • Comfort Circle Cassette Units
      • Deco Fan Coil Units
      • Isotherm Fan Coil Units
      • Modulair Fan Coil Units
Menu back  

Replacement Parts

  • 1.2 Drain Tray Front

    Brookvent Aircycle 1.2 Replacement Drain Tray

    HRV systems generate considerable amounts of moisture due to their high Heat Recovery Efficiency; this moisture must be drained from the system to a suitable discharge location. The Aircycle 1.2 is supplied complete with a centralised drainage connection on the bottom of the unit.

    You must ensure that the drain tray is firmly secured and is clear of any debris, we would recommend you remove and clean if it is necessary. Product Code: AR 90-05-139

    If you have any questions regarding this procedure, please get in contact with the office on 02890616505 or hello@brookvent.co.uk

    BUY NOW - Via Whatsapp

  • 1.2 Front Filter Cover Set

    Brookvent Aircycle 1.2/1.3/1.3+ Filter Cover Set (AS 90-09-908)

    These replacement covers are the front cover tabs that protect your MVHR filters.

    Product Code: (AS 90-09-908)

    BUY NOW - Via Whatsapp

  • 13

    Brookvent Aircycle 1.2/1.3/1.3+ Front Panel Kit

    Product Code: AS 90-09-904

    Please indicate on checkout in the “

    BUY NOW - Via Whatsapp

  • 1.2 PCB – Front

    Brookvent Aircycle 1.2/1.3/1.3+ PCB Kit

    In the unlikely event of an electronic PCB failure, the Aircycle 1.3’s PCB module can be disconnected and replaced.

     

    Step 1. PCB replacement should only be completed by a qualified Electrician.
    Step 2. Ensure all circuits are isolated before working on the unit.
    Step 3. When handling the PCB’s ensure the devices are grounded to prevent electrostatic discharge from damaging the components.
    Step 4. To locate the PCB in the correct position; line the feet A & B on the PCB along the edge of the enclosure as shown.
    Step 5. Also line the edge of foot A shown against the yellow stand-off in the enclosure.
    Step 6. This will ensure that the spindles line up with the holes in the enclosure lid.
    Step 7. For inverted units (white label) line foot A up with the opposite edge and with the yellow stand off on the bottom right (i.e. the same position as the one being replaced).
    Step 8. Wire the PCB as shown on the other page (note there are two sensors wired in the interface terminal, the unit may not work if only one is wired).
    Step 9. When the unit is wired and fixed in place; insert the spindles in the potentiometers.
    Step 10. To do this ensure all the potentiometers are turned fully anti-clockwise.
    Step 11. Insert the spindles with the slot in the direction shown.
    Step 12. Replace the cover and screw it in place.
    Step 13. Re-connect the power.
    Step 14. Recommission the system.

     

    If you have any questions regarding this procedure, please get in contact with the office on 02890616505 or hello@brookvent.co.uk

    https://brookvent.co.uk/product/aircycle-1-3-house-ventilation-system/

     

     

    BUY NOW - Via Whatsapp

  • 1.2-1.3-Wall-Bracket-Kit-Front-1024×215

    Brookvent Aircycle 1.2/1.3/1.3+ Wall Bracket Kit

    A  Brookvent Aircycle 1.2,1.3 and 1.3+Replacement Wall Bracket Kit. Product Code: AS 90-09-909

    The unit should be attached to the wall using the wall bracket provided, please ensure the mounting surface can safely bear the load of the unit using suitable screw fixings.

    Step by Step Instructions for Wall Mount:

    Remove the existing bracket which will be secured to the back of the unit and replace with new one.

    The second bracket should be secured to the mounting surface (wall)  Please ensure the brackets are level.

    The unit can then be set onto the mounting surface with the lip of each bracket

    Ensure the system is level when fully mounted.

    Ensure the unit is fully attached and secure.

    If you have any questions regarding this procedure, please get in contact with the office on 02890616505 or hello@brookvent.co.uk

    https://brookvent.co.uk/product/aircycle-1-3-house-ventilation-system/

    BUY NOW - Via Whatsapp

  • Heat Exchange Core Front

    Brookvent Aircycle 1.3 Replacement Heat Exchanger Core

    The Aircycle 1.3 Heat Recovery Core is protected by two filters. As long as the filters are regularly changed as detailed in the previous section there should be no need to access the system’s heat recovery core. However, should regular filter changes not be adhered to it may be advisable to access the system’s heat recovery core, and where required, clear it of any debris that may have collected.

    Step By Step Process:

    Step 1. Isolate the unit from the mains and ensure all supply circuits are disconnected. Never run the system with the MVHR heat exchange core removed.
    Step 2. Remove both filters.
    Step 3. Remove the front door panel via its 8 screws.
    Step 4. Remove the foam panels and then the heat exchanger from the unit by pulling the plastic strip running across the front of the heat exchanger.
    Step 5. Carefully remove any dust from the heat exchanger with a household vacuum cleaner. Do not attempt the clean the heat exchanger with any fluids.
    Step 6. Carefully reinsert the replacement heat exchange core into the unit and the foam panels.
    Step 7. Reinsert both filters (change if necessary) and replace the front door ensuring all four screws are securely fastened. Also ensure the filter tabs on the front of the unit are securely fitted.
    Step 8. Power the unit on at the isolator and ensure any supply circuits are reconnected.

    Product Code: AS 90-09-906

    If you have any questions regarding this procedure, please get in contact with the office on 02890616505 or hello@brookvent.co.uk

    https://brookvent.co.uk/product/aircycle-1-3-house-ventilation-system/

    BUY NOW - Via Whatsapp

  • 1.3 Fan Kit Front

    Brookvent Aircycle 1.3/1.3+ Individual Fan Kit

    The Aircycle 1.3 heat recovery system has a very straight forward fan replacement process should the unlikely event of a failure. Product Code: AS 90-09-901

    The Step Process:
    Step 1. Isolate the unit from the mains and ensure all supply circuits are disconnected.
    Step 2. Unscrew the front cover (4 No. screws) and remove the cover.
    Step 3. Unplug the two leads from the fan.
    Step 4. Unscrew the locking screw on the fan mount.
    Step 5. Turn the fan mount anti-clockwise to the line marked on the fan case and then pull straight out.
    Step 6. Place the new replacement component assembly in the case, lining it up with the line marked in the case. Push inward until flush with the front case and then turn clockwise to tighten.
    Step 7. Refit the locking screw and connect the cables
    Step 8. Re-fit the front cover and secure with the screws.
    Step 9. Power the unit on at the isolator and ensure any supply circuits are reconnected. The unit will not need to be re-commissioned as the controller will hold the settings.

    If you have any questions regarding this procedure, please get in contact with the office on 02890616505 or hello@brookvent.co.uk

    https://brookvent.co.uk/product/aircycle-1-3-house-ventilation-system/

    BUY NOW - Via Whatsapp

  • Heat Exchange Core Front

    Brookvent Aircycle 1.3+ Replacement Heat Exchanger Core

    The Aircycle 1.3 Heat Recovery Core is protected by two filters. As long as the filters are regularly changed as detailed in the previous section there should be no need to access the system’s heat recovery core. However, should regular filter changes not be adhered to it may be advisable to access the system’s heat recovery core, and where required, clear it of any debris that may have collected.

    Step By Step Process:

    Step 1. Isolate the unit from the mains and ensure all supply circuits are disconnected. Never run the system with the MVHR heat exchange core removed.
    Step 2. Remove both filters.
    Step 3. Remove the front door panel via its 8 screws.
    Step 4. Remove the foam panels and then the heat exchanger from the unit by pulling the plastic strip running across the front of the heat exchanger.
    Step 5. Carefully remove any dust from the heat exchanger with a household vacuum cleaner. Do not attempt the clean the heat exchanger with any fluids.
    Step 6. Carefully reinsert the replacement heat exchange core into the unit and the foam panels.
    Step 7. Reinsert both filters (change if necessary) and replace the front door ensuring all four screws are securely fastened. Also ensure the filter tabs on the front of the unit are securely fitted.
    Step 8. Power the unit on at the isolator and ensure any supply circuits are reconnected.

    Product Code: AS 90-09-905

    If you have any questions regarding this procedure, please get in contact with the office on 02890616505 or hello@brookvent.co.uk

    https://brookvent.co.uk/product/aircycle-1-3-house-ventilation-system/

    BUY NOW - Via Whatsapp

  • 1.2 PCB – Front

    Brookvent Aircycle 3.1 Dial operated PCB kit.

    In the unlikely event of an electronic PCB failure, the Aircycle 3.1’s PCB module can be easily disconnected and replaced. Product Code: AS 90-09-801

    Step By Step Process:

    Step 1. Isolate the unit from the mains and ensure all supply circuits are disconnected.
    Step 2. Disconnect the mains from the fused spur.
    Step 2. Unscrew the two large screws in the front of the control panel and pull out the PCB assembly.
    Step 3. Unplug all the leads, the connectors are all marked to match up with their corresponding internal connections.
    Step 4. Feed the mains cable from the replacement assembly through the unit and out the through the hole in the back plate.
    Step 5. Connect all the cables back up ensuring to connect each cable to the correctly marked connector.
    Step 6. Replace the assembly in the pocket and secure in place with the screws.
    Step 7. Connect the mains to the fused spur.
    Step 8. Power the unit on at the isolator and ensure any supply circuits are reconnected. The unit will need to be re-commissioned.

     

    BUY NOW - Via Whatsapp

  • 3.1 back fan

    Brookvent Aircycle 3.1 Individual Fan Fit

    The aircycle 3.1 heat recovery system has a very straight forward fan replacement process should the unlikely event of a fan failure occur. Product Code: AS 90-08-800

    Step by Step Process:
    Step 1. Isolate the unit from the mains and ensure all supply circuits are disconnected.
    Step 2. Unscrew the side plugs and remove.
    Step 3. Remove the side panel.
    Step 4. Unplug the two leads from the fan.
    Step 5. Unscrew the scroll assembly from the casing and remove the scroll assembly. This Whole assembly should be returned to Brookvent.
    Step 6. Place the new scroll assembly in the recess in the case and ensure the holes line up with the screw insert. Fix the scroll assembly to the case.
    Step 7. Re-plug the connectors (they are two different types so they cannot be mixed up).
    Step 8. Re-fit the end panel.
    Step 9 fit the side plugs, (the long plug always fits in the centre hole), and screw to fix.
    Step 10. Power the unit on at the isolator and ensure any supply circuits are reconnected. The unit will not need to be re-commissioned as the controller will hold the settings

    If you have any questions regarding this procedure, please get in contact with the office on 02890616505 or hello@brookvent.co.uk

    https://brookvent.co.uk/product/aircycle-3-1-house-ventilation-systems/

    BUY NOW - Via Whatsapp

  • Heat Exchange Core Front

    Brookvent Aircycle 3.1 Replacement Heat Exchanger Core

    The Aircycle 3.1 Heat Recovery Exchange Core is protected by two filters. As long as the filters are regularly changed as detailed in the previous section there should be no need to access the system’s heat recovery core. However, should regular filter changes not be adhered to it may be advisable to access the system’s heat recovery core, and where required, clear it of any debris that may have collected.

    Step By Step Process

    Step 1. Isolate the unit from the mains and ensure all supply circuits are disconnected. Never run the system with the MVHR heat exchange core removed.
    Step 2. Remove the front door panel via its 4 screws.
    Step 3. Remove both filters.
    Step 4. Remove the heat exchanger from the unit by pulling the plastic strip running across the front of the heat exchanger.
    Step 5. Carefully remove any dust from the heat exchanger with a household vacuum cleaner. Do not attempt the clean the heat exchanger with any fluids.
    Step 6. Carefully reinsert the new heat exchange core into the unit.
    Step 7. Reinsert both filters (change if necessary) and replace the front door ensuring all four screws are securely fastened. Also ensure the filter tabs on the front of the unit are
    securely fitted.
    Step 8. Power the unit on at the isolator and ensure any supply circuits are reconnected.

    Product Code: AS 90-09-803

    If you have any questions regarding this procedure, please get in contact with the office on 02890616505 or hello@brookvent.co.uk

     

    BUY NOW - Via Whatsapp

  • 31

    Brookvent Aircycle 3.1/4.1 Front Panel Kit

    Product Code: AS 90-09-810

    Please indicate in the order notes which version you need (e.g. 3.1 or 4.1)

    BUY NOW - Via Whatsapp

  • AC3.1-4-Wall-Bracket-Kit-1024×344

    Brookvent Aircycle 3.1/4.1 Wall Bracket Kit

    A  Brookvent Aircycle 3.1/4.1 Replacement Wall Bracket Kit.  Product Code: AS 90-09-806.

    The unit should be attached the to the wall using the wall bracket provided, please ensure the mounting surface can safely bear the load of the unit using suitable screw fixings.

    Step by Step Instructions for Wall Mount:

    Remove the existing bracket which will be secured to the back of the unit and replace with new one.

    The second bracket should be secured to the mounting surface (wall)  Please ensure the brackets are level.

    The unit can then be set onto the mounting surface with the lip of each bracket

    Ensure the system is level when fully mounted.

    Ensure the unit is fully attached and secure.

    If you have any questions regarding this procedure, please get in contact with the office on 02890616505 or hello@brookvent.co.uk

    https://brookvent.co.uk/product/aircycle-3-1-house-ventilation-systems/

    BUY NOW - Via Whatsapp

Ducting, Accesories & Filters
  • Introduction
  • airduct FIREBRICK
  • Rigid PVC Ducting
  • Semi Rigid Ducting
  • Attenuation
  • Fire Sleeve
  • Filters
  • Accessories
  • Replacement Parts
  • Valves and Grilles
Latest news
  • easter
    Happy Easter from Brookvent
    April 2, 2026
  • louvre belfast
    Brookvent Brings Louvre Production Home to Belfast
    January 9, 2026
  • Merry Christmas and Happy New Year from Brookvent
    December 19, 2025
  • black friday
    Black Friday 2025 Deals – Biggest Sale of the Year!
    November 6, 2025
Latest blogs
  • Door louvre
    Discover the Brookvent Door Louvre – Learn How It Can Improve Your Space!
    January 13, 2026
  • louvre belfast
    Brookvent Brings Louvre Production Home to Belfast
    January 9, 2026
  • lourve
    Brookvent Louvre Vents – All you need to know
    November 25, 2025
  • ventilation louvre
    Choosing the Right Ventilation Louvre
    November 10, 2025
Got a question? Get in touch

    Name*

    Email*

    Location*

    Message

    How did you find Brookvent?

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    • Amazon integration
    • About
    • News
    • Blog
    • Delivery & Returns
    • Terms & Conditions
    • Privacy Policy – Brookvent
    • Sitemap
    • Amazon
    Brook House, Dunmurry Industrial Estate, Dunmurry, Belfast, Co. Antrim, BT17 9HU
    Tel: +44 (0)28 9061 6505 / Fax: +44 (0)28 9061 6518 / Email: hello@brookvent.co.uk
    Registered in Northern Ireland with Company No: NI 019735

    © 2026 Website by WDMA

    Brookvent UK and Ireland

    Typically replies within minutes

    Any questions related to Replacement Parts?

    WhatsApp Us

    🟢 Online | Privacy policy

    WhatsApp us