Brookvent Aircycle 3.1/4.1 Front Panel Kit
Product Code: AS 90-09-810
Please indicate in the order notes which version you need (e.g. 3.1 or 4.1)
HRV systems generate considerable amounts of moisture due to their high Heat Recovery Efficiency; this moisture must be drained from the system to a suitable discharge location. The Aircycle 1.2 is supplied complete with a centralised drainage connection on the bottom of the unit.
You must ensure that the drain tray is firmly secured and is clear of any debris, we would recommend you remove and clean if it is necessary. Product Code: AR 90-05-139
If you have any questions regarding this procedure, please get in contact with the office on 02890616505 or hello@brookvent.co.uk
£42.00 + VAT
Brookvent Aircycle 3.1/4.1 Front Panel Kit
Product Code: AS 90-09-810
Please indicate in the order notes which version you need (e.g. 3.1 or 4.1)
BUY NOW - Via Whatsapp
Brookvent Aircycle 3.1/4.1 Wall Bracket Kit
A Brookvent Aircycle 3.1/4.1 Replacement Wall Bracket Kit. Product Code: AS 90-09-806.
The unit should be attached the to the wall using the wall bracket provided, please ensure the mounting surface can safely bear the load of the unit using suitable screw fixings.
Step by Step Instructions for Wall Mount:
Remove the existing bracket which will be secured to the back of the unit and replace with new one.
The second bracket should be secured to the mounting surface (wall) Please ensure the brackets are level.
The unit can then be set onto the mounting surface with the lip of each bracket
Ensure the system is level when fully mounted.
Ensure the unit is fully attached and secure.
If you have any questions regarding this procedure, please get in contact with the office on 02890616505 or hello@brookvent.co.uk
https://brookvent.co.uk/product/aircycle-3-1-house-ventilation-systems/
BUY NOW - Via Whatsapp
Brookvent Aircycle 3.1 Individual Fan Fit
The aircycle 3.1 heat recovery system has a very straight forward fan replacement process should the unlikely event of a fan failure occur. Product Code: AS 90-08-800
Step by Step Process:
Step 1. Isolate the unit from the mains and ensure all supply circuits are disconnected.
Step 2. Unscrew the side plugs and remove.
Step 3. Remove the side panel.
Step 4. Unplug the two leads from the fan.
Step 5. Unscrew the scroll assembly from the casing and remove the scroll assembly. This Whole assembly should be returned to Brookvent.
Step 6. Place the new scroll assembly in the recess in the case and ensure the holes line up with the screw insert. Fix the scroll assembly to the case.
Step 7. Re-plug the connectors (they are two different types so they cannot be mixed up).
Step 8. Re-fit the end panel.
Step 9 fit the side plugs, (the long plug always fits in the centre hole), and screw to fix.
Step 10. Power the unit on at the isolator and ensure any supply circuits are reconnected. The unit will not need to be re-commissioned as the controller will hold the settings
If you have any questions regarding this procedure, please get in contact with the office on 02890616505 or hello@brookvent.co.uk